Pause
Read
CEA vacancy search engine

3D ultrasound imaging using orthogonal row and column addressing of the matrix array for ultrasonic NDT


Thesis topic details

General information

Organisation

The French Alternative Energies and Atomic Energy Commission (CEA) is a key player in research, development and innovation in four main areas :
• defence and security,
• nuclear energy (fission and fusion),
• technological research for industry,
• fundamental research in the physical sciences and life sciences.

Drawing on its widely acknowledged expertise, and thanks to its 16000 technicians, engineers, researchers and staff, the CEA actively participates in collaborative projects with a large number of academic and industrial partners.

The CEA is established in ten centers spread throughout France
  

Reference

SL-DRT-25-0016  

Direction

DRT

Thesis topic details

Category

Technological challenges

Thesis topics

3D ultrasound imaging using orthogonal row and column addressing of the matrix array for ultrasonic NDT

Contract

Thèse

Job description

This thesis is part of the activities of the Digital Instrumentation Department (DIN) in Non-Destructive Testing (NDT), and aims to design a new, fast and advanced 3D ultrasound imaging method using matrix arrays. The aim will be to produce three-dimensional ultrasound images of the internal volume of a structure that may contain defects (e.g. cracks), as realistically as possible, with improved performance in terms of data acquisition and 3D image computation time. The proposed method will be based on an approach developed in medical imaging based on Row and Column Addressed (RCA) arrays. The first part will focus on the development of new data acquisition strategies for matrix arrays and associated ultrafast 3D imaging using RCA approach in order to deal with conventional NDT inspection configurations. In the second part, developed methods will be validated on simulated data and evaluated on experimental data acquired with a conventional matrix array of 16x16 elements operating in RCA mode. Finally, a real-time proof of concept will be demonstrated by implementing the new 3D imaging methods in a laboratory acquisition system.

University / doctoral school

Physique et Ingénierie: électrons, photons et sciences du vivant (EOBE)
Paris-Saclay

Thesis topic location

Site

Saclay

Requester

Position start date

01/10/2025

Person to be contacted by the applicant

IAKOVLEVA Ekaterina ekaterina.iakovleva@cea.fr
CEA
DRT/DIN//LA2C
CEA Saclay
Bâtiment 565
91191 Gif-sur-Yvette


33-(0)1 69 08 56 12

Tutor / Responsible thesis director

CHATILLON Sylvain sylvain.chatillon@cea.fr
CEA
DRT/DIN
CEA Saclay
Bâtiment 565
91191 Gif-sur-Yvette
+331 69 08 68 07

En savoir plus


https://list.cea.fr/fr/